New Products - ANV-DCB02
Two Door TCP/IP Control Board

  • Description
  • SPECIFICATIONS
  • DOWNLOAD

Description

          Features
The ANV- DCB02 is a 2-Door Access Control Board. can connect up to 4 proximity readers (2 for each door). If want to have anti-passback or to know who is coming and going, will need a reader on the entrance side of the door, and one on the exit side of that same door. Otherwise, will only need a reader on the entrance side and an exit button on the exiting side. There are enough connections on this 2 door access control board to wire up electronic locks, sensors, exit button and alarms.
This is a very easy access control panel to work with. All connect a Cat5 Ethernet cable from the RJ45 Port on the Control Board to network and any PC on network can access the board and all its functions using Free Access Control Software.
– Control of Memory up to 20,000 Users / up to 100,000 Event Buffers.
– Network Communication via TCP/IP.
– Real time supervision; photo display; mass storage; flexible user privilege setup; remote unlocking; multi-user supervision; quick setting; convenient checking and query; alarm function.
– In addition, Professional function for professional users such as bank,cash house, telecom station, power supply station, prison and police station: interface locking; intimidation alarm; integrated fire control;anti-passback and anti-tail.

Model ANV-DCB02
Communication TCP/IP 10M/100M adaptive
Size of PCB board 160mm *106mm
Size of Case 273mm*228mm*65mm
Power Supply 12VDC 4-7A
Power Consumption of Circuit Board Less than 100mA
Input Format of Reader Wiegand 26 (All card reader with compatible protocol, such as Motorola, HID, EM, Mifare one etc)
Quantity of Readers 4 Pcs
Door Controled 2 pairs
Door opening time extending setting 1-600 seconds(adjustable)
Max q'ty of controller No limit
Operation Temperature - 40 C~70 C
Operation Humidity 10-90 % RH , No Condensation
Q'ty of users 20,000 Users
Q'ty of Event Buffers(offline) 100,000 event buffers
Power interruption protection measure High Speed Memory,Records never lose
Max Distance from Reader to Controller 100m (suggestion distance 80m)
Max Distance between Controllers  

RS232:Communication Distance less than 13m,suggestion distance is 3m or less
RS485:bus line max length 1200m,suggestion length 1000m or less,if expansion device added,the distance could be 3000m.
TCP/IP:Depends on net coverage area

Alarm for long time door open, illegal break in,intimidate Yes
Open and close door at long time  Yes
Urgency locking  Yes

Name Size Download
ANV-DCB02 Two Door TCP/IP Control Board251 KB